How much roof insulation? Thickness, Rd and Rc

Required thickness depends on the product’s thermal conductivity and the desired resistance. The example table explains the difference; a roof assessment determines the suitable build-up.

Roofing photograph
Illustrative roofing image; not a diagnosis of the photographed roof.

Required thickness depends on the product’s thermal conductivity and the desired resistance. The example table explains the difference; a roof assessment determines the suitable build-up.

Rd, Rc and lambda in plain language

Lambda (λ), in W/(m·K), describes thermal conductivity. At equal thickness, lower conductivity gives higher resistance. Rd is the insulation layer’s resistance in m²·K/W; Rc refers to the construction and is not automatically the same as a board’s Rd. Framing and junctions matter.

How to read the thickness calculation

For a homogeneous layer: thickness in metres = target Rd × lambda. Rd 4.5 with lambda 0.035 gives 0.1575 m, or 15.75 cm. The table rounds up to whole centimetres. These selected inputs are calculation examples, not product advice, legal minimums or subsidy approval. Order using the exact product’s declared Rd and thickness.

How many square metres are needed?

Measure the actual insulated surface, not just the room’s floor area. A sloping roof has more surface than its horizontal projection. Openings, edge strips and the layout determine cutting waste; one standard waste allowance does not suit every roof. State both net insulated area and supply assumptions.

Moisture and junctions determine performance

Assess existing layers and vapour behaviour before adding insulation. Internal insulation of a flat roof needs particular care and can cause moisture problems in an unsuitable build-up. Coordinate airtightness, vapour control, roof height, outlets and ventilation. A thicker board cannot repair a leak or gap.

Examples: insulation thickness in centimetres

Calculation examples, not required thicknesses or subsidy conditions. Rounded up; excludes finishes, air layers and structure. The selected λ values are examples, not fixed values for material families. Rd in m²·K/W.
Selected λ (W/m·K)Rd 3.5Rd 4.5Rd 6.0
0.0228 cm10 cm14 cm
0.03513 cm16 cm21 cm
0.04014 cm18 cm24 cm

Insulation materials and checks

Insulation materials and checks
MaterialApplicationWhat to check
PIR / PUR boardsRigid boards in a compatible roof build-upDeclared Rd, facings, joints and fire performance
Glass wool / stone woolRolls or boards; product depends on applicationAvoid gaps and compression; roof boards need suitable load performance
EPSLightweight foam boardsCompressive strength, temperature and compatibility
XPSIncluding suitable inverted roofsWater exposure, drainage and system design
Wood fibreFlexible or rigid productsMoisture behaviour, weight and suitability
CelluloseBlown into suitable enclosed cavitiesFill density, settlement and airtight enclosure
Flax, hemp, cork and sheep woolProduct-specific bio-based optionsLambda, additives, moisture and fire behaviour
Cellular glassSpecific load-bearing insulation systemsComplete system and installation
Vacuum panels and aerogelSpecialist solutions for restricted spaceDetail design, protection and product limits
Milieu Centraal — dakisolatie en dakopbouwSOPREMA — dakafdichting en isolatiesystemen

Related information

Read this article in Dutch
Call usWhatsAppRequest a quote